Field Service Copilot
This study describes a voice assistant for maintenance technicians that works with no network at all, in places such as plants, mines, power stations and water treatment sites.
| Showcase record | |
|---|---|
| Showcase category | Case studies |
| Industry | Industrial field maintenance |
| Published | 6 August 2026 |
This study describes a voice assistant for maintenance technicians that works with no network at all, in places such as plants, mines, power stations and water treatment sites.
At a glance
| The problem | Where connectivity is unreliable or deliberately absent, cloud assistants cannot be used, and repair time depends on which expert can be reached. |
| The approach | A rugged edge unit reads live plant data without writing to it, searches manuals, procedures and incident history stored on the device, and answers by voice with the manual section cited. |
| Technology | AMD Kria KR260, a 4-bit quantized language model, local retrieval over plant documents and read-only access to plant protocols. |
| Measures and results | The study defines what to baseline before deployment, including mean time to repair and first-time fix rate. It reports no measured results. |

The Business Problem
Where the work happens
Maintenance technicians work in factories, oil and gas plants, mines, power stations, water treatment sites and remote installations. In most of them connectivity is unreliable. In many of them it is deliberately absent, because the operational network is air gapped or segmented as a matter of security policy.
That makes a cloud hosted copilot impractical precisely where expert help is most valuable. The assistant that works beautifully in a demonstration on the corporate network is unavailable in the plant room.
Why cloud assistants do not solve it
- Phone a senior engineer. Who may be in another time zone, on another site, or unavailable.
- Search paper or PDF manuals. Hundreds of pages, often for a slightly different equipment revision.
- Guess from experience. Which works well for experienced technicians and poorly for new ones.
- Escalate. Which converts a thirty minute inspection into a multi day specialist visit.
The consequence is that mean time to repair is driven by who is available rather than by what is actually wrong.
Where the cost sits
| Cost | Driver |
|---|---|
| Unplanned downtime | Diagnosis time, not repair time, is usually the larger share of the outage. |
| Specialist travel | Escalations that turn out to be routine once someone experienced looks. |
| Repeat visits | First time fix rate falls when the technician cannot confirm the cause on site. |
| Unnecessary parts | Components replaced on suspicion rather than on evidence. |
| Expert time | Senior engineers spending their day answering the same questions by phone. |
| Knowledge loss | Decades of failure mode experience leaving with retirement. |
The Requirement in One Sentence
Give the technician standing in front of the machine a grounded first hypothesis, drawn from live sensor readings, the equipment documentation and this asset's own incident history, with the manual section cited, and with no network of any kind.
Solution Overview
A Kria KR260 in a rugged enclosure, carried to the asset or installed in the plant room. It reads live state through the plant’s own protocols, searches a knowledge base built at commissioning, correlates the two, and answers out loud with citations. Nothing about the plant leaves the plant.
Layered architecture
| Layer 6 Interaction | Voice in, voice and screen out | Industrial microphone and rugged tablet, usable with gloves and hearing protection. |
| Layer 5 Reasoning | 4-bit quantized language model | Correlates live readings against documented failure modes and prior incidents. |
| Layer 4 Knowledge | Local retrieval over the plant corpus | Manuals, diagrams, SOPs, maintenance logs, sensor specifications and incident history. |
| Layer 3 Live state | Read only plant acquisition | Vibration, temperature, pressure, controller state and historian trend. |
| Layer 2 Acceleration | Fabric and DPU offload | Audio front end and dequantization, keeping the cores free for orchestration. |
| Layer 1 Platform | KR260 in rugged enclosure | Sealed, conduction cooled, certified for the area classification where required. |
The hard boundary
The copilot observes. It does not write. There is no code path by which it can change a setpoint, force an output, acknowledge an alarm or modify a controller.
| The copilot does | The copilot never does |
|---|---|
| Read sensor and controller values | Write to any controller |
| Search plant documentation | Change a setpoint |
| Retrieve incident history | Acknowledge or clear an alarm |
| Propose a likely cause | Authorise an intervention |
| Cite the manual section | Bypass a permit to work |
| Estimate downtime | Replace the technician's judgement |
Why this boundary is non negotiable
Read only access is what makes the device approvable by an operations technology security team and by the site's safety authority. A copilot that could write would need to be treated as a control system, with all the assessment burden that carries, and it would not be permitted on most sites at all.
Hardware and Rugged Deployment
Compute and interfaces
| Element | Configuration |
|---|---|
| Platform | AMD Kria KR260 |
| System on module | Kria K26, Zynq UltraScale+ MPSoC |
| Memory | 4 GB on-module DDR4 |
| Acceleration | Programmable fabric with DPU |
| Storage | NVMe sized for the full plant knowledge base |
| Client | Rugged tablet over local wired or isolated wireless link |
| Audio | Industrial noise cancelling microphone and headset |
| Thermal camera | Optional, for surface temperature observation |
| Diagnostic interfaces | USB and serial for direct equipment interrogation |
| Plant interface | Read only tap onto the control network segment |
Two deployment shapes
- Portable. Carried to the asset in a sealed case, connected at the point of work. Suits sites with many assets and
few technicians. - Fixed. Installed in the plant room or motor control centre, accessed from a tablet anywhere on site. Suits
continuous process plants.
Environmental design
The enclosure is usually the harder engineering problem than the software, and it is frequently the item that determines whether the system can be deployed at all.
- Ingress protection appropriate to the environment. Dust in mining and cement, washdown in food and pharmaceutical, salt in marine and offshore.
- Conduction cooling. Sealed enclosures cannot use fans, so thermal design has to move heat through the case. This directly constrains sustained inference throughput.
- Vibration and shock. Both for portable use and for fixed installation near rotating equipment.
- Hazardous area certification. ATEX or IECEx where the site requires it. This is a long lead item and needs to be identified at the very start of the project.
- Wide operating temperature. Plant rooms, outdoor installations and desert or arctic sites all sit outside commercial temperature ranges.
Identify area classification first
If any target location is a classified hazardous area, that decision drives the enclosure, the power architecture, the certification timeline and the cost more than every software choice combined. Establish it in the first week, not in the first pilot.
The Knowledge Base
What goes in
Equipment manuals
Wiring and P&ID diagrams
Standard operating procedures
Maintenance logs
PLC and controller documentation
Sensor specifications
Historical incident records
Spare parts catalogue
Vendor service bulletins
Answer quality in this architecture is determined far more by the quality of this corpus than by the size of the model. A larger model on a poor corpus performs worse than a small model on a well built one, and it costs more to run.
Ingestion pipeline
| 01 | Layout aware document parsing | Tables, torque values, part numbers and procedure steps preserved as structure. |
| 02 | Diagram and scan handling | Optical character recognition on scanned drawings, with labels and tag numbers indexed separately from body text. |
| 03 | Asset tagging | Every chunk associated with the equipment tags it applies to, so retrieval can be scoped to the asset in front of the technician. |
| 04 | Section anchored chunking | Chunks follow document sections so a citation points somewhere findable. |
| 05 | Hybrid index build | Dense embeddings plus keyword matching, because tag numbers and part numbers are exact strings that similarity search handles badly. |
Incident history is the differentiator
Manuals describe how equipment fails in general. The maintenance log describes how this specific asset has actually failed, on this site, under this duty. Indexing both and correlating them is what turns adocument search into something a technician finds genuinely useful.
| Source | What it contributes |
|---|---|
| Manual failure mode table | The set of plausible causes for the symptom. |
| Sensor specification | What a normal reading looks like for this instrument. |
| Maintenance log | What has actually gone wrong on this asset before. |
| Prior incident record | What the fix was, how long it took, what parts were used. |
| Vendor bulletin | Known issues the manual predates. |
Ingestion is a project, not a step
Most industrial documentation is a mixture of good PDFs, scanned drawings from the 1990s and a spreadsheet somebody maintains privately. Budget for the ingestion work explicitly. It is the single most common reason this class of deployment underdelivers, and it is entirely predictable in advance.
Live Plant State Acquisition
Protocol coverage
| Protocol | Typical source |
|---|---|
| Modbus TCP and RTU | Instruments, drives, protection relays, legacy equipment. |
| OPC-UA | Modern controllers and the plant's structured data layer. |
| Siemens S7 | S7 family controllers where OPC-UA is not exposed. |
| Rockwell | ControlLogix and CompactLogix platforms. |
| BACnet | Building services, HVAC and utilities. |
| MQTT | Existing plant telemetry brokers where present. |
| Historian query | Trend context, so the copilot can see how a reading has moved rather than only where it is now. |
| Direct diagnostic | USB or serial interrogation of the equipment itself. |
Trend matters more than instant value
A vibration reading of 4.2 mm per second means little on its own. The same reading, having risen steadily from 1.8 over six weeks, means something specific. The acquisition layer therefore pulls a trend window from the historian wherever one is available, not just the current value.
Asset state object
Read only, enforced at several levels
Read only is enforced in the protocol client configuration, in the network segmentation, and where the site requires it in a hardware data diode. It is not a software policy that could be changed by a configuration mistake.
Correlation and Reasoning
What the model is asked to do
The reasoning task is narrow and well defined. Given a symptom, a set of live readings with their normal ranges and trends, the documented failure modes for this equipment, and this asset’s own history, produce a ranked hypothesis with the evidence for each and the manual section it comes from.
| 01 | Symptom captured from the technician | In their own words, with the asset identified by tag or by scanning it. |
| 02 | Live state read, scoped to that asset | Only the tags belonging to the asset and its immediate system. |
| 03 | Retrieval scoped to the asset tag | The pump manual, not every pump manual on site. |
| 04 | Correlation | Readings matched against documented failure signatures and against prior incidents. |
| 05 | Ranked hypothesis with citations | Most likely cause first, with what supports it and what would rule it out. |
Grounding contract
| Condition | Required behaviour |
|---|---|
| Strong documentary support | State the hypothesis and cite the section. |
| Readings without documentary support | Report the anomaly, state that the documentation does not cover it, do not speculate on cause. |
| No relevant documentation | Say so, and flag the corpus gap for the next ingestion cycle. |
| Safety relevant condition | Give the documented instruction without softening it, and prompt for the permit to work requirement. |
| Multiple plausible causes | Rank them and state the discriminating test for each. |
| Conflicting documents | Prefer the most recent vendor bulletin and say that guidance was updated. |
Citations are mandatory
Every substantive claim carries a document and section reference the technician can open on the tablet. That is what makes the answer verifiable before someone acts on it, and it is the single feature that most determines whether experienced technicians trust the system or ignore it.
Inference Stack and Memory Budget
Why four bit
A three billion parameter model at sixteen bit precision needs roughly six gigabytes for weights alone, against four gigabytes on the module. At four bit it comes down to approximately 1.7 gigabytes, leaving room for the speech models, the resident portion of a large retrieval index and the protocol stacks.
Throughput is bound by memory bandwidth rather than by arithmetic, because the full weight set streams out of DDR for every generated token. Halving the bytes per weight roughly doubles the
achievable rate.
| Component | Allocation |
|---|---|
| Quantized model weights | ~1.7 to 2.2 GB |
| Key value cache at working context | ~200 to 350 MB |
| Speech recognition and synthesis | ~135 MB |
| Retrieval index resident portion | ~200 to 400 MB |
| Protocol stacks and runtime | ~600 to 800 MB |
| Knowledge base on storage | Tens of gigabytes on NVMe, paged not resident |
Context is the tight constraint here
This use case wants longer context than the others, because a good answer often needs a failure mode table, a wiring note and two prior incidents at the same time. The key value cache grows linearly with context and competes with the weights for the same bandwidth, so context length is treated as a
budgeted resource with a hard cap rather than as something to be extended when answers seem thin.
The DDR pipeline
Tiling
Weights tiled to BRAM and URAM
Double buffering
Transfer overlapped with compute over AXI
Prefetch
Next layer fetched during the current one
On-fabric dequant
Four bit bytes cross the bus, not sixteen
Sealed enclosure, thermal reality
A conduction cooled sealed enclosure will throttle before an open bench will. Sustained throughput in the final enclosure at plant ambient is the only figure worth quoting, and it is measured in Phase 2 rather than estimated.
Security Architecture
Network position
The copilot is an operational technology asset and is treated as one. It sits where a monitoring device sits, not where a control device sits, and it has no path to the internet.
| Control | Implementation |
|---|---|
| Read only protocol clients | No write function is compiled into the acquisition layer. |
| Network segmentation | Placed on a monitoring segment with firewall rules permitting only the required read traffic. |
| Data diode | Available as a hardware option where the site requires physical enforcement of unidirectional flow. |
| No outbound path | No internet route in the reference design. Nothing to exfiltrate to. |
| Secure boot | On-module root of trust with signature verification at each stage. |
| Signed artefacts | Model, index and application verified before load, so a tampered corpus cannot change what the copilot tells a technician. |
| Physical security | Sealed enclosure, tamper evidence, encrypted storage at rest. |
Why this is the whole approval argument
An operational technology security team assesses a new device on two questions. Can it change anything, and can anything reach it from outside. This architecture answers no to both, by construction rather than by configuration, which is what makes the assessment tractable.
Standards context
The design aligns to the segmentation and zone and conduit model that industrial control system security standards expect. The copilot is placed as a monitoring asset within an existing zone, with defined conduits, rather than introducing a new trust boundary. Its exact placement is agreed with the site security team as part of Phase 0.
Access and accountability
- Technician identity recorded against every session, so answers can be traced to who received them.
- Query and answer log retained locally, with the citations, for review and for corpus improvement.
- No audio retained. Transcripts only, and only for the session unless diagnostic logging is explicitly enabled
Worked Example, End to End
Technician
"Why is Pump 6 vibrating?"
Step 1 Scope
Asset resolved to tag P-006
From the spoken reference, confirmed against the asset register.
Step 2 Read
Live vibration and temperature
4.2 mm/s against a normal below 2.8. Bearing housing at 71 degrees against a normal 45 to 60.
Step 3
Six week history from the historian
Both readings rising steadily rather than stepping, which discriminates wear from a discrete event.
Step 4 Retrieve
Manual and history for this asset
Failure mode table from the pump manual, plus one prior incident on P-006 seven months ago.
Step 5 Correlate
Signature matched
Rising vibration with rising bearing temperature matches the documented bearing wear signature, not the cavitation or misalignment signatures.
Copilot
"Most likely bearing wear on the drive end. Vibration is at 4.2 against a normal below 2.8, and the bearing housing is at 71 degrees against a normal of 45 to 60. Both have risen steadily over six weeks rather than stepping, which fits wear rather than a sudden fault. The same failure occurred on this pump seven months ago. Inspection is recommended. Estimated downtime is 35 minutes. See manual section 6.4, bearing failure modes."
Follow up
| Technician | "Could it be cavitation instead?" |
| Copilot | "Less likely. The manual describes cavitation as a broadband vibration signature with suction pressure below the required margin, and suction pressure is currently within range. If you want to rule it out, section 6.2 gives the suction pressure check." |
Offline Operation and Lifecycle
Keeping a disconnected system current
An offline system that is never updated becomes wrong. The design uses signed knowledge bundles delivered through whatever channel the site already trusts, rather than requiring a permanent connection.
| Build | Corpus ingested and indexed centrally | New manuals, revised procedures and closed incident records folded into the next bundle. |
| Sign | Bundle signed and versioned | Model, index and application versioned together. |
| Transfer | Physical media or scheduled connection | Whatever the site's existing controlled update route is. |
| Verify and activate | Signature checked before load | Previous bundle retained for rollback. |
| Harvest | Local logs collected at the same visit | Refusals and corpus gaps drive the next ingestion cycle. |
The feedback loop that matters
Every question the copilot could not answer is a documented gap in the plant’s knowledge base. Over time that list is more valuable than the copilot itself, because it identifies exactly which equipment the site cannot support from its own documentation.
Delivery phases
| Phase | Scope | Exit criteria |
|---|---|---|
| Phase 0 Assessment |
Asset scope, documentation audit, protocol survey, area classification, OT security engagement. | Corpus readiness report and agreed network placement. |
| Phase 1 Ingestion |
Documentation collected, parsed, tagged and indexed. Gaps identified and closed where possible. | Retrieval accuracy measured on a real question set. |
| Phase 2 Bench and enclosure |
Model characterised on KR260 in the target enclosure at plant ambient. | Sustained throughput and thermal behaviour measured. |
| Phase 3 Advisory pilot |
Deployed on one asset class with a small technician group. Answers reviewed against outcomes. | Answer accuracy and citation quality accepted by maintenance leadership. |
| Phase 4 Site rollout |
Additional asset classes, additional technicians, update cycle established. | MTTR and first time fix targets held. |
| Phase 5 Multi site |
Bundle production industrialised across sites. | Repeatable deployment package. |
Benefits and Measurement
Benefits realised
| Completely offline | Works in plants and remote sites with no connectivity, by design rather than by degraded fallback. |
| Faster troubleshooting | Live readings and documentation correlated in one step instead of several. |
| Less expert dependency | A junior technician reaches a senior level first hypothesis without a phone call. |
| Secure plant deployment | Read only by construction, no outbound path, nothing about the plant leaves the plant. |
| Lower MTTR | Repair time driven by the fault rather than by who is available to answer the phone. |
| Higher first time fix | Cause confirmed on site before the technician leaves. |
| Institutional memory | Prior incidents on the same asset surface automatically instead of living in one person's head. |
| Documented knowledge gaps | Every unanswered question maps exactly where the site's documentation is thin. |
KPI framework
| Measure | What it tells you |
|---|---|
| Mean time to repair | The headline number, and the one the business case rests on. |
| Diagnosis time share | How much of the outage was working out what was wrong. |
| First time fix rate | Repeat visits avoided. |
| Escalation rate | Specialist callouts avoided. |
| Expert phone minutes | Senior engineer time recovered. |
| Unnecessary part replacement | Components changed on suspicion rather than evidence. |
| Refusal and corpus gap rate | Where to invest the next ingestion cycle. |
| Citation follow rate | Whether technicians are verifying, which indicates trust. |
Baseline first
Capture current MTTR, first time fix rate and escalation rate before deployment. In maintenance these are usually recorded somewhere in the CMMS, which makes this the easiest of the four use cases to build a defensible before and after picture.
Engineering Considerations and Risks
Known hard problems
| Risk | Mitigation |
|---|---|
| Documentation quality | Corpus audit in Phase 0 with an explicit ingestion budget. This is the dominant determinant of answer quality and it is knowable up front. |
| Area classification | Established in the first week, because certification is a long lead item that governs enclosure, power and cost. |
| Thermal throttling in a sealed case | Sustained throughput measured in the final enclosure at plant ambient, never on an open bench. |
| Technician trust | Mandatory citations, a visible refusal path, and an advisory pilot with a small group before wider rollout. |
| Stale knowledge base | Signed bundle cycle with a defined update cadence, and corpus revision recorded in every answer. |
| OT security approval | Read only enforced in the client, the segmentation and optionally in hardware. Engage the security team in Phase 0, not at deployment. |
| Acoustic environment | Close talking headset rather than far field capture, and hearing protection compatible hardware. |
| Tag naming inconsistency | Asset register reconciliation, with aliases learned from the query log. |
Open questions for the customer
- Which fleet manager is in use, and what interface does it expose for plan submission and state
subscription? - Does a warehouse management system integration exist that can supply load identifiers, or is the world
model limited to fleet state only? - Are instructions issued from fixed stations, roaming headsets, or both?
- What is the authorisation model? Can any operator issue any instruction, or is it role based?
- Which languages and how many sites are in scope for the first release?
- Who is the safety authority for the installation, and what evidence will they want that the language
layer cannot reach a safety function?
Recommended first step
A corpus readiness assessment on one asset class. It costs little, it produces a measured retrieval accuracy against real technician questions, and it tells you honestly whether the documentation supports this before any hardware is bought. If the corpus is not there, that finding is worth having early rather than after a pilot underperforms.
Source
- Tech4Biz Showcase, collected on 26 November 2026.